9XCite™RS‐232/485RFModem–ProductManualv2.1[2007.01.04]
©2007MaxStream,Inc. 9
2.2. RS-485 (2-wire) Operation
2.2.1. DIP Switch Settings and Pin Signals
Note: Refer to the figures in the “RS-485/422 Connection Guidelines” section for RJ-45 connector
pin designations used in RS-485/422 environments.
2.2.2. Wiring Diagram
Figure2‐09. XCiteRFModeminanRS‐485(2‐wire)half‐duplexenvironment
Table2‐02. RS‐485(2‐wirehalf‐duplex)signalsandtheirimplementati onsontheXCiteRFModem
DB-9 Pin RS-485 Name Description Implementation
2 T/R- (TRA) Negative Data Line Transmit serial data to and from the RF modem
5 GND Ground Signal Ground
8 T/R+ (TRB) Positive Data Line Transmit serial data to and from the RF modem
9PWR Power
Optional power input that is connected internally
to the front power connector
1, 3, 4, 6, 7 not used
Figure2‐06.
RS‐485(2‐wire)Half‐duplex
DIPSwitchSettings
Figure2‐07.
PinsusedonthefemaleRS‐232(DB‐9)
SerialConnector
Figure2‐08.
RS‐485(2‐wire)w/Termination(optional)
Terminationisthe120ΩresistorbetweenT+andT‐.
DIPSwitchsettingsarereadandapplied
onlywhilepowering‐on.