Digi ConnectPort Network Device Podręcznik Użytkownika Strona 1

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Networking Digi ConnectPort Network Device. Digi ConnectPort Network Device User`s guide [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 149
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
ConnectPort
®
LTS
Users Guide
ConnectPort LTS 8, ConnectPort LTS 8 MEI,
ConnectPort LTS 8 W, ConnectPort LTS 8 MEI W,
ConnectPort LTS 16, ConnectPort LTS 16 MEI,
ConnectPort LTS 16 W, ConnectPort LTS 16 MEI W,
ConnectPort LTS 16 MEI 2AC
ConnectPort LTS 32, ConnectPort LTS 32 MEI,
ConnectPort LTS 32 W, ConnectPort LTS 32 MEI W
90001001_C
Przeglądanie stron 0
1 2 3 4 5 6 ... 148 149

Podsumowanie treści

Strona 1 - 90001001_C

ConnectPort® LTS User’s Guide ConnectPort LTS 8, ConnectPort LTS 8 MEI, ConnectPort LTS 8 W, ConnectPort LTS 8 MEI W, ConnectPort LTS 16, Conne

Strona 2

10 The ConnectPort LTS Family ConnectPort LTS (Linux Terminal Server) products provide serial over Ethernet connectivity for applications today and i

Strona 3 - Contents

100  Peer configuration: Specifies how the remote IP address that is supplied to the client is assigned. - Automatically Obtain IP Address fro

Strona 4

101 Configuration through the command line Configuring a ConnectPort LTS product through the command-line interface consists of entering a series of

Strona 5

102 Verify device support of commands On the configuration specific shell interface, online help is available to verify whether a ConnectPort LTS pro

Strona 6

103 To configure: Use this command: system-identifying information set system serial port options--general set serial serial TCP and serial UDP set t

Strona 7 - 1. About this guide

104 To configure: Use this command: Python set python Trace log set trace Syslog set syslog

Strona 8 - Digi contact information

105 Configuration through Simple Network Management Protocol (SNMP) Configuring ConnectPort LTS products through Simple Network Management protocol u

Strona 9 - 2. Introduction

106 4. Monitoring and management The port, device, system, and network activities of ConnectPort LTS products can be monitored from a variety of inte

Strona 10 - Features

107 General system information The General page displays the following general system information about the ConnectPort LTS product, which can be use

Strona 11

108 Power status For models with dual power supply, Power status shows the status of the power supplies. For example, if power supply 1 for a Connect

Strona 12

109 Serial port information The Serial page of System Information lists the serial ports that are configured for the ConnectPort LTS product. Click

Strona 13

11 Quick reference for configuring features This guide primarily focuses on configuration, monitoring, and administration tasks from the web interfac

Strona 14

110 Serial statistics The Serial statistics section of serial port information includes data counters and error tracking that will help determine the

Strona 15

111 Network statistics Network statistics are detailed statistics about network and protocol activity that may aid in troubleshooting network communi

Strona 16 - IP protocol support

112 TCP statistics Segments Received Segments Sent Number of segments received or sent. Active Opens Number of active opens. In an active open, the C

Strona 17

113 UDP statistics Datagrams Received Datagrams Sent Number of datagrams received or sent. Bad Datagrams Received Number of bad datagrams that were r

Strona 18

114 XBee Network This section is used to view more detailed statistics for XBee module activity that may aid in troubleshooting network communication

Strona 19

115 Python Application XBee Socket Counters This section includes data counters that are specific to ZigBee Sockets implemented using a Python applic

Strona 20

116 Manage connections and services The Management menu is for viewing and managing connections and services for the ConnectPort LTS product. Manage

Strona 21

117 Monitoring capabilities from the command line There are several commands for monitoring ConnectPort LTS products and managing their connections.

Strona 22

118 info The info command displays statistical information about a device over time. The statistics displayed are those gathered since the tables con

Strona 23 - Modem emulation

119 set alarm set alarm displays alarm settings, including conditions that trigger alarms, and how alarms are sent, either as an email message, an SN

Strona 24 - Security features

12 Feature/task Path to feature in the web interface Help on configuring features Help button on each page. Host name for a device Configuration >

Strona 25 - Configuration management

120 Commands for managing connections and sessions  close: Closes active sessions that were opened by connect, rlogin, and telnet commands.  conn

Strona 26 - Network services

121 Monitoring Capabilities from SNMP Device monitoring capabilities from SNMP include, among other things:  Network statistics, defined in RFC 121

Strona 27

122 5 Administration tasks This chapter discusses the administration tasks that need to be performed on ConnectPort LTS products periodically, such

Strona 28 - Network/serial clients

123 File management The File Management page of the web interface uploads custom files to a ConnectPort LTS product. Custom files allow the flexibili

Strona 29

124 Backup/restore device configurations Once a ConnectPort LTS product is configured, backing up the configuration settings is recommended in case p

Strona 30 - Configuration interfaces

125 Backup/restore device configuration from a TFTP or BOOTP Server from the command line From the command-line interface, the ―backup‖ command backs

Strona 31

126 Update firmware The firmware for a ConnectPort LTS product can be updated in several ways:  In the web interface, by the Administration >

Strona 32

127 Restore a device configuration to factory default settings Restoring a ConnectPort LTS product to its factory default settings clears all current

Strona 33 - The Web interface

128 Using the Reset button If the ConnectPort LTS device cannot be accessed from the web interface, the configuration can be restored to factory defa

Strona 34 - Command-line interface

129 Display system information System information displays the model, MAC address, firmware version, and bios version of the ConnectPort LTS product.

Strona 35

13 Python support: loading and running custom programs authored in the Python programming language. Configurable from command line only. See the set

Strona 36 - LCD panel

130 Administration from the command-line interface Administrative tasks can also be performed from the command line. Here are several device-administ

Strona 37

131 6 LCD interface: configuration, monitoring, and diagnostics This chapter discusses how to configure, monitor or diagnose the ConnectPort LTS usi

Strona 38 - Administration tasks

132 Keypad operations When you turn on the ConnectPort LTS, the following default image is displayed on the LCD screen: Pressing any key displays th

Strona 39 - 3. Configuration

133 Configuration using the LCD interface You can set the following configurations using the LCD interface:  IP settings #1: Sets IP mode, IP addre

Strona 40

134 Set IP Address If you select IP Mode to STATIC, you can change or set the IP address, subnet mask and gateway settings. When you select IP ADDRES

Strona 41 - Open the web interface

135 After changing the selected letter, you can choose another letter by pressing Ext key twice. Repeat the steps to change the letter as described a

Strona 42

136 Change the hostname Enter the host name menu by selecting CONFIGURATION and then HOST NAME. The following menu is displayed: Press the Sel key a

Strona 43

137 After changing the selected letter, choose another letter by pressing Ext key twice. Repeat the steps to change the letter just described above.

Strona 44

138 Change the DNS configuration Select CONFIGURATION and then DNS. The following menu is displayed: Press the Sel key again. The following menu is

Strona 45

139 Monitoring using the LCD interface The following information can be monitored through the LCD interface.  Serial port - Configuration: Profi

Strona 46

14 Simple Network Management Protocol (SNMP): Configure SNMP through the web interface Configuration > System > Simple Network Management Proto

Strona 47

140 Miscellaneous functions in LCD interface The Miscellaneous menu has the following functions.  Factory Reset: Restore the configuration to facto

Strona 48

141 LED Settings When you enter the LCD setting menu by selecting MISCELLANEOUS and then LCD SETTINGS, the following menu is displayed: Reset RESE

Strona 49

142 7 Disaster recovery The Digi ConnectPort LTS unit provides a disaster recovery procedure in the event the configuration data is destroyed or cor

Strona 50

143 6. Enter the information for the first menu items. - Protocol: The choices are BOOTP or TFTP. - IP address assigned: Enter the IP address of

Strona 51

144 8 Hardware specifications Hardware specifications for this product are located at: http://www.digi.com/products/serialservers/connectportlts#spe

Strona 52

145 9 Regulatory Information and Certifications FCC certifications and regulatory information (USA only) FCC Part 15 Class B These devices comply

Strona 53

146 Modifications (FCC 15.21) Changes or modifications to this equipment not expressly approved by Digi may void the user’s authority to operate this

Strona 54

147 Safety statements 5.10 Ignition of Flammable Atmospheres Warnings for Use of Wireless Devices Observe all warning notices regarding use of wire

Strona 55

148 Rack-mountable: 1. Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperatu

Strona 56

149 Lithium Battery CAUTION Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by

Strona 57

15 Hardware and network interface features For detailed hardware specifications and network interface information, go to: http://www.digi.com/product

Strona 58

16 IP protocol support All ConnectPort LTS products include a robust on-board TCP/IP stack with a built-in web server. Supported protocols include, u

Strona 59

17 Following is an overview of some of the services provided by these protocols. Serial data communication over TCP and UDP ConnectPort LTS products

Strona 60

18 Auto-IP Auto-IP is a protocol that will automatically assign an IP address from a reserved pool of standard Auto-IP addresses to the computer on w

Strona 61 - Serial port settings

19 Secure Sockets Layer (SSL)/Transport Layer Security (TLS) Secure Sockets Layer (SSL)/Transport Layer Security (TLS) are used to provide authentica

Strona 62

2 © Digi International Inc.2012. All Rights Reserved. Digi, Digi International, the Digi logo, ConnectPort, XBee, and RealPort are trademarks or regi

Strona 63

20 Point-to-Point Protocol (PPP) The Point-to-Point Protocol (PPP) transports multi-protocol packets over point-to-point links. PPP encapsulates the

Strona 64

21 IP address assignment alternatives There are several ways to assign an IP address to a ConnectPort LTS product:  Static IP: Assign a specific IP

Strona 65

22 RealPort software ConnectPort LTS products use the patented RealPort COM/TTY port redirection for Microsoft Windows, UNIX, and Linux environments.

Strona 66

23 Alarms ConnectPort LTS products can be configured to issue alarms, in the form of email message or SNMP traps, when certain device events occur. T

Strona 67

24 Security features Security-related features in ConnectPort LTS products include:  Secure access and authentication: – One password, one permiss

Strona 68

25 Configuration management Once a ConnectPort LTS product is configured and running, configuration-management tasks need to be periodically performe

Strona 69

26 Supported connections and data paths ConnectPort LTS products allow for several kinds of connections and paths for data flow between the ConnectPo

Strona 70

27  Reverse SSH: An SSH connection is made to a ConnectPort LTS product, in which data is passed transparently between the SSH connection and a nam

Strona 71

28 Network/serial clients A network/serial client connection is one in which a ConnectPort LTS product initiates a network connection or opens a seri

Strona 72

29 Command-line interface (CLI)-based client connections Command-line interface based client connections are available for use once a user has establ

Strona 73

3 Contents Contents ...

Strona 74

30 Configuration capabilities and interfaces This is an overview of the configuration capabilities and interfaces for ConnectPort LTS products; Chapt

Strona 75

31 Digi Device Discovery utility The Digi Device Discovery utility locates Digi devices on a network and allows for opening the web interface for dis

Strona 76

32 Advantages of the Digi Device Discovery utility are:  It quickly locates Digi devices and basic device information, such as the device address,

Strona 77 - System settings

33 The Web interface A web interface is provided as an easy way to configure and monitor ConnectPort LTS products. Configurable features are groupe

Strona 78

34 Command-line interface ConnectPort LTS products can be configured by issuing commands from the command line. The command-line interface allows c

Strona 79

35 Simple Network Management Protocol (SNMP) Simple Network Management Protocol (SNMP) is a protocol for managing and monitoring network devices. The

Strona 80

36 Standard MIBs supported The standard MIBs supported in ConnectPort LTS products are:  MIB-II (RFC 1213) This is a MIB for managing a TCP/IP netw

Strona 81 - User settings

37 Monitoring capabilities and interfaces There are several capabilities and interfaces for monitoring ConnectPort LTS products and managing their co

Strona 82

38 LCD panel The LCD panel can be used to perform several monitoring tasks. For more information, see LCD interface: configuration, monitoring, and d

Strona 83

39 3. Configuration This chapter describes how to configure a ConnectPort LTS product. It covers these topics:  "Alternate methods for assigni

Strona 84

4 The Web interface ... 33 Command-line in

Strona 85

40 Configure an IP address from the command-line interface The set network command configures an IP address from the command line. Include the follow

Strona 86 - Peripheral

41 Configuration through the web interface Configuring ConnectPort LTS products through the web interface involves these tasks:  Change the IP addr

Strona 87

42 By using the Digi Device Discovery utility Alternatively, use the Digi Device Discovery Utility to locate the ConnectPort LTS product and open i

Strona 88

43 Discover devices 1. From the start menu, select Start > Programs > Digi Connect > Digi Device Discovery. The Digi Device Discovery app

Strona 89

44 For ConnectPort LTS models with multiple power supplies, such as the ConnectPort LTS 16 MEI 2AC, the Home page displays a power failure message ab

Strona 90 - Applications

45 Organization of the web interface When web interface is opened, the Home page is displayed. Here is the home page for the ConnectPort LTS: The Ho

Strona 91

46 Home page display differences for multiple-power-supply models For ConnectPort LTS models with multiple power supplies, such as the ConnectPort LT

Strona 92

47 Configuration pages The choices under Configuration in the menu display pages for configuring settings for various features, such as network setti

Strona 93 - PPP configuration

48 Restore the ConnectPort LTS product to factory defaults The device configuration can be reset to factory defaults as needed during the configurati

Strona 94

49 Change the IP address from the web interface, as needed Normally, IP addresses are assigned to ConnectPort LTS products through DHCP. This procedu

Strona 95

5 Monitoring capabilities from the command line ... 117 Commands for displaying dev

Strona 96

50 Network configuration settings The Network configuration pages include:  Ethernet IP settings: For viewing IP address settings and changing as n

Strona 97

51 Ethernet IP settings The Ethernet IP settings configure how the IP address of the ConnectPort LTS product is obtained, either by DHCP or by usin

Strona 98

52  IPv6: Internet Protocol version 6 configuration. Do not use this interface: Choose this option if you do not want to enable IPv6 address on t

Strona 99

53 Basic Network Services Settings The Basic Network Services page shows a set of common network services that are available for ConnectPort LTS prod

Strona 100

54 Supported basic network services and their default network port numbers In Digi devices that have multiple serial ports, the network port number d

Strona 101 - Access the command line

55 The table shows network services, services provided, and the default network port number for each service. Service Services provided Default netwo

Strona 102

56 Service Services provided Default network port number Telnet Server Allows users an interactive Telnet session to the ConnectPort LTS product comm

Strona 103

57 Advanced Network Services Settings The Advanced Network Services page shows a set of specific network services that are available for ConnectPort

Strona 104

58  Samba Settings : Enable: Enable or disable the Samba service. Samba server name: IP address or DNS name of the Samba server. Mounting on

Strona 105

59 Socket tunnel settings A Socket Tunnel can be used to connect two network devices: one on the ConnectPort LTS product’s local network and the othe

Strona 106 - 4. Monitoring and management

6 5.10 Ignition of Flammable Atmospheres ... 147 Potentially Hazardous Atmosphere

Strona 107

60 Advanced network settings The Advanced Network Settings are used to further define the network interface, including:  Host name: The Host name t

Strona 108

61 Serial port settings Use the Serial Port Configuration page to establish a port profile for the serial port of the ConnectPort LTS product. This p

Strona 109

62 RealPort profile The RealPort profile maps a COM or TTY port to a serial port. This profile configures a ConnectPort LTS product to create a virtu

Strona 110

63 TCP Sockets profile The TCP Sockets profile allows serial devices to communicate over a TCP network. The TCP Server allows other network devices t

Strona 111

64 UDP Sockets profile The UDP Sockets profile allows serial devices to communicate using UDP. The UDP Server configuration allows the serial port to

Strona 112

65 Modem Emulation profile The Modem Emulation profile allows a Digi device to send and receive modem responses to the serial device over the Etherne

Strona 113

66 Local Configuration profile The Local Configuration profile allows access to the command-line interface when connecting from a serial terminal. Cu

Strona 114

67 Basic serial settings After selecting a port profile, the profile settings are displayed. Choose the appropriate features for your environment. He

Strona 115

68 Advanced serial settings The advanced serial settings further define the serial interface, including whether port buffering (also known as port lo

Strona 116

69 TCP settings The TCP Settings are displayed only when the current serial port is configured with the TCP Sockets or the Custom Profile. The settin

Strona 117

7 1. About this guide Purpose This guide describes and shows how to configure, monitor, and administer ConnectPort LTS products. Audience This guide

Strona 118

70 Send after the following number of idle: Send the data after the specified number of milliseconds has passed with no additional data received on

Strona 119

71 Authentication Settings The authentication settings set the authentication method and related settings. The ConnectPort LTS supports following aut

Strona 120

72 For Radius authentication, the following settings are required. Primary authentication server: The IP address or DNS name of authentication serv

Strona 121

73  LDAP: When selected, user who registered the database of LDAP server specified can only access the serial port. There are several categories of

Strona 122 - 5 Administration tasks

74 Port group settings As a convenience feature, port groups can be created to send data to multiple ports. Instead of sending data to individual ser

Strona 123 - File management

75 Alarms Use the Alarms page to configure device alarms or display current alarms settings. Device alarms are used to send email messages or SNMP tr

Strona 124

76 Alarm conditions To configure an alarm, click on it. The configuration page for individual alarms has two sections:  Alarm Conditions: For speci

Strona 125

77 Enable and Disable Alarms Once alarm conditions are configured, enable and disable individual alarms by selecting or deselecting the Enable checkb

Strona 126

78 SNMP configuration settings Simple Network Management Protocol (SNMP) is a protocol that can be used to manage and monitor network devices. Connec

Strona 127

79  Enable Simple Network Management Protocol (SNMP) traps: Enables or disables the generation of SNMP traps. Trap version: SNMP version for the

Strona 128

8 Additional product information on www.digi.com In addition to the previous documents, product information is available on the Digi website, www.dig

Strona 129

80 Date and Time Settings System Date and Time can be changed on this configuration page. Authentication Settings The authentication settings for sys

Strona 130

81 User settings User settings involve several areas:  User authentication: whether authentication is required for users accessing the ConnectPort

Strona 131

82 Password authentication By default, Digi Connect Family devices have password authentication enabled. That means when a login prompt is displayed

Strona 132 - Keypad operations

83 Add users Digi Connect Family products allow multiple users to be defined. For those products, the Users Configuration page shows the currently de

Strona 133 - Change IP settings

84 User permissions settings The User Permissions page is used to define whether and how users can use services and configuration settings for the Co

Strona 134

85 User permissions and effects Permission Setting Effect None The user does not have permission to execute this setting. Read Self The user can disp

Strona 135

86 Peripheral SD Memory The ConnectPort LTS supports standard SD and SDHC (high-capacity) memory cards. To use an SD memory device, insert the car

Strona 136 - Change the hostname

87 Modem ConnectPort LTS W has an internal modem that is configured it on this page. The Modem configuration page has the same configuration settings

Strona 137

88 LCD ConnectPort LTS has an LCD display and you can configure it on this page. The LCD configuration page has  Enable display: If checked, LCD

Strona 138 - Change the DNS configuration

89 XBee The XBee configuration page has very similar settings to the Custom serial port profile. Once Allow direct access from networks is checked, y

Strona 139

9 2. Introduction This chapter introduces ConnectPort LTS products, types of supported connections and data paths, and the interface options availabl

Strona 140 - Factory Reset

90 Applications Additional configurable applications are accessed from the main menu under Applications. Some devices have an Applications link under

Strona 141 - LED Settings

91 Digi Developer Community Wiki: The Digi Developer Community Wiki is a place to learn about developing solutions using Digi’s software and serv

Strona 142 - 7 Disaster recovery

92 Auto-start settings The Auto-start Settings page configures Python programs to execute when the ConnectPort LTS product boots. Up to four auto-sta

Strona 143

93 PPP configuration PPP (Point-to-point Protocol) provides TCP/IP communication over a modem connected to a serial port on your ConnectPort LTS serv

Strona 144 - 8 Hardware specifications

94  Authentication configuration - User Name: Specifies the username for this connection. The username, along with the password, are specified by

Strona 145 - FCC Part 15 Class B

95  Peer configuration: Specifies how the remote IP address that is supplied to the client is assigned. - Automatically Assign Remote IP Address

Strona 146 - Declaration of Conformity

96 Setting up incoming PPP connections To configure the correct settings for incoming PPP connections, you need to configure settings on Application

Strona 147 - Safety statements

97 5. In the Peer Configuration section, select an option for assigning the IP address of incoming PPP client. Automatically assign remote IP addres

Strona 148 - Rack-mountable:

98 Settings on Serial ports 1. Select a port from Configuration -> Serial ports -> Ports Settings 2. Change the port profile to modem 3. In

Strona 149 - Cabling

99 Outgoing PPP Connection Outgoing PPP connections are those connections where the ConnectPort LTS product dials-up to an external modem or ISP. Exa